<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Uncategorized - The Civil Technology &amp; Consultant</title>
	<atom:link href="https://civiltechc.com/category/uncategorized/feed/" rel="self" type="application/rss+xml" />
	<link>https://civiltechc.com</link>
	<description>Innovative Technology for Modern Structures</description>
	<lastBuildDate>Tue, 12 Jul 2022 18:35:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://civiltechc.com/wp-content/uploads/2023/03/cropped-sdfdfw-32x32.jpg</url>
	<title>Uncategorized - The Civil Technology &amp; Consultant</title>
	<link>https://civiltechc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Concerning BNBC 2020</title>
		<link>https://civiltechc.com/2022/07/12/concerning-bnbc-2020/</link>
					<comments>https://civiltechc.com/2022/07/12/concerning-bnbc-2020/#respond</comments>
		
		<dc:creator><![CDATA[bhanss7911]]></dc:creator>
		<pubDate>Tue, 12 Jul 2022 18:32:19 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://civiltechc.com/?p=302</guid>

					<description><![CDATA[<p>Section 2.5.8 for static analysis requirements is deemed to be satisfied in buildings that fulfillthe following two conditions: (a) The building period in the two main horizontal directions issmaller than both 4TC (TC is defined in Sec 2.5.4.3) and 2 seconds. (b) There are noirregularities in the structure.In section 2.5.8, dynamic analysis should be performed for the following buildings: (a)regular buildings with a height greater than 40 m in Zones 2, 3, and 4 and greater than 90 min Zone 1. (b) irregular structures with a height of more than 12 m in Zones 2, 3, and 4 andmore than…</p>
<p>The post <a href="https://civiltechc.com/2022/07/12/concerning-bnbc-2020/">Concerning BNBC 2020</a> first appeared on <a href="https://civiltechc.com">The Civil Technology & Consultant</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Section 2.5.8 for static analysis requirements is deemed to be satisfied in buildings that fulfill<br>the following two conditions: (a) The building period in the two main horizontal directions is<br>smaller than both 4TC (TC is defined in Sec 2.5.4.3) and 2 seconds. (b) There are no<br>irregularities in the structure.<br>In section 2.5.8, dynamic analysis should be performed for the following buildings: (a)<br>regular buildings with a height greater than 40 m in Zones 2, 3, and 4 and greater than 90 m<br>in Zone 1. (b) irregular structures with a height of more than 12 m in Zones 2, 3, and 4 and<br>more than 40 m in Zone 1.<br>For irregular buildings, smaller than 40 m in height in Zone 1, dynamic analysis, even though<br>not mandatory, is recommended.<br>Observation is here if we consider the floor height of a building is 3.0 m, and approximately a<br>20 story (for 2.0 S) regular building can be designed through static analysis in seismic zones 2,<br>3, and 4 as per section 2.5.6. But, as per section 2.5.8, dynamic analysis is essential for regular<br>buildings with heights greater than 40 m (13 story approx.) in Zones 2, 3, and 4. Which one<br>will be considerable?</p><p>The post <a href="https://civiltechc.com/2022/07/12/concerning-bnbc-2020/">Concerning BNBC 2020</a> first appeared on <a href="https://civiltechc.com">The Civil Technology & Consultant</a>.</p>]]></content:encoded>
					